<ul id="yaegq"></ul>
  • <tfoot id="yaegq"></tfoot>
    <tfoot id="yaegq"></tfoot>
  • <tfoot id="yaegq"></tfoot>
  • <strike id="yaegq"></strike>
    <ul id="yaegq"><sup id="yaegq"></sup></ul>
    <strike id="yaegq"><rt id="yaegq"></rt></strike>
    <li id="yaegq"><abbr id="yaegq"></abbr></li>
    <ul id="yaegq"></ul>
    歡迎來到上海宸喬生物科技有限公司網(wǎng)站!
    咨詢熱線

    18801803238

    當前位置:首頁   >  產(chǎn)品中心  >  Ultrasep ES液相色譜柱  >  Ion Exchangers(離子交換)  >  Anion Exchanger SAX W Quick Columns

    Anion Exchanger SAX W Quick Columns

    簡要描述:These anion exchangers are so called ?permanently loaded“ ion exchangers. They exhibit the excellent performance of silicas and the good stability of RP-phases, which leads to low costs.

    • 產(chǎn)品型號:
    • 廠商性質:生產(chǎn)廠家
    • 更新時間:2024-08-07
    • 訪  問  量:1666

    詳細介紹

    Anion Exchangers

     

    UltraSep ES SAX W (Anorganic ions according to DIN 38405)

      

    These anion exchangers are so called „permanently loaded“ ion exchangers. They exhibit the excellent performance of silicas and the good stability of RP-phases, which leads to low costs.

    Stability of UltraSep ES SAXW with phthalic acid/TRIS buffer (1.25/2.5 mM) at pH 6.4

      

    Permanently loaded ion exchangers are not only useful to separate inorganic ions (see Application ANION1) but also to separate natural products with aqueous buffers (nucleotides). They cannot be used with organic-aqueous eluents

    Our permanently loaded ion exchangers are easily to regenerate. For this, we offer a special solution or a regeneration in our firm. 

    If there is a need to chromatograph aqueous solutions highly contaminated with organic material, we recommend to use additionally a RP precolumn (length 33 mm) in front of the precolumn cartridge ( ANION2 Tap water from Berlin).

    By lowering of the strength of the eluent, phosphate appears between nitrite and bromide without the necessity to increase the pH noticeably  In this way, there are good conditions for the conductivity detection too. Furthermore, fluoride is well separated from the injection peak (see Application ANION3).

        
     

    UltraSep ES SAX W Quick Columns

      

    See Applications ANION5 and ANION6

     

    UltraSep ES SAX W33 (Determination of ascorbic acid)

      

    See Applications ANION9

     

    UltraSep ES SAX NN (Rapid determination of nitrite, nitrate, and bromide in drinking water and foodstuffs)

      

    By this exchanger concentrations of nitrite and nitrate can be determined considerably faster and more sensitive than with customary methods. Nitrate, which can be determined by the photometric method only relatively insensitively, is determined by chromatography at 220 nm without previous enrichment to 0.1 mg/l. Bromide is determined at 210 nm with high sensitivity.

    Iodide can be determined also directly at 225 nm. For a quick determination of iodide you can use a column of  UltraSep ES SAX NN with a length of 33 mm.

    The selectivity and rapidity of the determination (phosphoric acid as eluent) can be changFor columns with endcapped packings an additional charge of 10.00 € is calculated.  ed by the pH value (at best pH 3 – 5). Furthermore,  the velocity of elution can also be varied by the concentration of phosphoric acid (at best 10 – 30 mM; see Application ANION4).

       
     

    UltraSep ES RP NN (Determination of nitrite, nitrate, bromate and bromide in drinking water and foodstuffs)

      See Applications ANION7 and ANION8

     

     

    Examples of Analyzed Compounds

    Analyzed in Application
    (AN = ANION)

    Go to

     

    Ascorbic acid

    AN9

    ANION1

     

    Bromate

    AN7, AN8

    ANION2
     

    Bromide

    AN1, AN3, AN4, AN5, AN6, AN7

    ANION3

     

    Carbonate

    AN2

    ANION4

     

    Chloride

    AN1, AN2, AN3, AN5, AN6

    ANION5

     

    Fluoride

    AN3

    ANION6

     

    Nitrate

    AN1, AN3, AN4, AN5, AN6, A7

    ANION7

     

    Nitrite

    AN1, AN3, AN4, AN5, AN6, A7

    ANION8

     

    Phosphate

    AN3, AN6

    ANION9

     

    Sulfate

    AN1, AN2, AN3, AN5, AN6

     

     

     

     

     

     

     

     

     

     

    COLUMNS and  PRICES  ()
     Column size (mm)
    150 x 3125 x 360 x 333 x 3
    UltraSep ES SAX W 270.00  
    UltraSep ES SAX W Guard column RP 18 *   125.00
    UltraSep ES SAX W QC  255.00250.00
    UltraSep ES SAX QCM 270.00  
    UltraSep ES SAX NN  265.00245.00
    UltraSep ES RP NN240,00240,00  
    UltraSep ES SAX W33 295,00  
    * Recommended as precolumn for samples with high content of organic substances.

     

    Size (mm)

     
      10 x 35 x 3 ***  
    Precolumn cartridges
    (Price per pack = 5 pieces)
     170.00170.00
    Activator for ES SAX W (1 ml)12.00  
    Regeneration solution (30 ml) for regeneration by customer33.00  
    *** Only for UltraSep ES SAX W QC.

    產(chǎn)品咨詢

    留言框

    • 產(chǎn)品:

    • 您的單位:

    • 您的姓名:

    • 聯(lián)系電話:

    • 常用郵箱:

    • 省份:

    • 詳細地址:

    • 補充說明:

    • 驗證碼:

      請輸入計算結果(填寫阿拉伯數(shù)字),如:三加四=7

    聯(lián)系我們

    上海宸喬生物科技有限公司 公司地址:上海市阿克蘇路1187號516室   技術支持:化工儀器網(wǎng)
    • 聯(lián)系人:王經(jīng)理
    • QQ:3004300903
    • 公司傳真:021-59100893-802
    • 郵箱:sales@keyanwang.com.cn

    掃一掃 更多精彩

    微信公眾號

    網(wǎng)站二維碼

    主站蜘蛛池模板: 欧美成人777| 成人欧美一区二区三区在线观看| 国产成人av一区二区三区不卡| 国产69久久精品成人看| 久久成人福利视频| 成人免费公开视频| 久久成人无码国产免费播放| 窝窝午夜看片成人精品| 国产激情一区二区三区成人91| 国产成人亚洲精品无码av大片| 久久久久国产成人精品| 成人毛片100免费观看| 午夜成人理论福利片| 成人毛片免费网站| 亚洲精品成人网站在线播放| 成人免费看吃奶视频网站| 亚洲欧洲国产成人精品| 国产精品成人无码视频| 日韩成人精品日本亚洲| 亚洲精品午夜国产va久久成人 | 久久亚洲色www成人欧美| 成人毛片18女人毛片免费| 69成人免费视频无码专区| 亚洲国产成人精品女人久久久| 国产精品成人va在线观看| 成人影院在线观看视频| 欧美成人午夜视频| 欧美成人第一页| 日本成人在线播放| 日本成人免费网站| 成人无码免费一区二区三区| 欧美成人免费一级人片| 日韩精品无码成人专区| 欧美成人免费高清视频| 成人黄色电影在线观看| 老司机成人影院| 精品成人一区二区三区免费视频| 亚洲国产成人无码av在线播放| 亚洲最大成人网色香蕉| 久久久久成人精品无码| 欧美成人午夜做受视频|